How To Change Reli On Thermometer Back To Fahrenheit
8 9
Taking a Reading
Note: Many pediatricians recommend the apply of ear thermometers for children
older than 6 months.
1. Press and release the Browse button. Afterward two seconds,
the system will perform a cocky-test,
Fig. 1, and show the
last temperature taken along with a flashing "°F" to indicate
the unit of measurement is ready for measurement,
Fig. two.
ii. Gently insert the probe snugly into the ear culvert until a
slight resistance is felt. The thermometer will beep when
the auto-position sensor detects proper placement. If the
unit does NOT beep, gently reposition the thermometer.
Annotation: To disable the auto-position sensor, immediately press
the SCAN button afterwards inserting the thermometer into the ear
canal.
3. Later on the unit of measurement beeps, press the Scan push,
Fig. iii, and
promptly release the button. The device will beep once
again after the measurement is complete.
Notation: If you practice Non printing the Scan button once information technology is
placed in the ear canal, the thermometer will automatically
take a measurement in 9 seconds.
4. If the measurement is below 100.4°F (38°C), the
thermometer will beep once and the measurement will be
shown on the display with a happy confront symbol,
Fig. 4.
v. If the temperature is 100.iv°F (38°C) or to a higher place, the thermometer volition sound
one long beep followed past 2 curt beeps. The measurement volition be shown
on the brandish with a sad confront symbol to signal fever,
Fig. 5.
6. Thermometer will automatically beep and close off later approximately one
minute of non-use.
NOTE: To ensure accuracy,
ane. Please wait at least x seconds between successive readings.
two. Make clean the probe lens before and after each utilise.
Fig. ii
Fig. 1
Changing Modes
Temperature readings can be displayed in either Fahrenheit
or Celsius. To switch between °F or °C, press and hold the
Browse button. Without releasing, also press the 'G' button
and toggle betwixt the modes,
Fig. 1 and 2.
Recalling Measurements in Retentiveness
The concluding 10 measurements taken are automatically
stored into memory. To recall measurements, press
the Browse button to plough the unit of measurement on. After the unit
beeps, press the 'Chiliad' button to view measurements in
retentivity. Continue to press the 'M' push button to view the
next previously stored measurement,
Fig. 1. The unit
will beep each time a recorded measurement is viewed.
Replacing the Battery
Your Instant Ear Thermometer requires one lithium bombardment, blazon CR2032.
The battery needs to be replaced when the depression battery symbol appears
on the display.
To replace the bombardment:
1) Slide the battery comprehend off.
2) Using a not-metal pointed tool, advisedly
remove the battery and insert the new battery
with the positive (+) side facing up.
three) Replace the battery comprehend.
NOTE: Delight properly dispose the bombardment away
from small children and heat.
Fig. ane
Fig. two
Memory
Symbol
Index
Fig. 1
Fig. three
Fig. iv
Fig. 5
Source: http://personalcare.manualsonline.com/manuals/mfg/relion/thermometer.html?p=5
Posted by: smileyfres1968.blogspot.com
0 Response to "How To Change Reli On Thermometer Back To Fahrenheit"
Post a Comment